- Other Mining Machinery[2]
- Separation Equipment[1]
- Multifunctional Materials[5]
- Telecommunication Tower[2]
- Mobile Phone Chargers[1]
- Solar Energy Systems[2]
- Villas[4]
- Slate[5]
- Artificial Stone[2]
- Bricks[8]
- Steel Wire[10]
- Springs[7]
- Other Fasteners[1]
- Metal Building Materials[3]
- Jacks[1]
- Pumps[1]
- Other Electronic Components[1]
- Wall Lamps[7]
- Semi-Precious Stone Crafts[7]
- Steel Pipes[7]
- Nonwoven Fabric[1]
- Mattresses[2]
- Other Food & Beverage[1]
- Spherical Roller Bearings[1]
- Cylindrical Roller Bearings[1]
- Contact Person : Ms. Jiang Xuan
- Company Name : Anshan Shenyuanhua Material Trade Co., Ltd.
- Tel : 86-412-6352555
- Fax : 86-412-6344111
- Address : Liaoning,Anshan,No 65, 325 Jia,Yuan Lin Road, Tiedong District, Anshan City, Liaoning Province. China
- Country/Region : China
- Zip : 114000
Thermal Insulation Brick
Thermal Insulation Brick
Product specification and masonry method
Wall thickness (mm) | Dimension (mm) | Masonry method | Wall heat transmission coefficient (W/m2·k) |
280 | 240x260x90 | Full-filling, ‘row-lock wall formed by stretcher course and header course in turn’, the wall is internally sandwiched with a polystyrene board of 80mm thickness. | 0.35 |
Half-filling, ‘row-loc wall formed by stretcher course and header course in turn’, the wall is internally sandwiched with polystyrene board of 80mm thickness. | 0.48 | ||
Full-filling, common stretcher course masonry method. | 0.41 | ||
310 | 240x290x90 | Full-filling, ‘row-lock wall formed by stretcher course and header course in turn’, the wall is internally sandwiched with a polystyrene board of 90mm thickness. | 0.31 |
Half-filling, ‘row-lock wall formed by stretcher course and header course in turn’, the wall is internally sandwiched with a polystyrene board of 90mm thickness. | 0.44 | ||
Full-filling, common stretcher course masonry method | 0.36 |
Product Characteristics
Good heat preserving performance
After being on-site traced and tested by the national construction material test centre, the average heat conducting coefficient of each kind of masonry wall made of Non-load-bearing thermal is less than 0.50, which may accord with the requirement of energy conservation for above 65%.
High engineering quality
Non-load-bearing thermal with average compressive strength of above MU3.5, low water absorption and small dry shrinkage may solve the common quality fault that the non-load bearing wall surface cracks and the big problem that the externally hung heat insulating material and the main body construction cannot be synchronized in service life perfectly.
Low construction
Non-load-bearing thermal is convenient in construction without external heat insulating process, so as to reduce the construction cost by 30% and largely increase the secure performance of the construction.
Thermal Insulation Brick